<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Protección Diferencial Industrial | Revalco</title>
	<atom:link href="https://www.revalco.es/categoria-producto/productos-revalco/proteccion-diferencial-industrial/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.revalco.es</link>
	<description>Revalco &#124; Material eléctrico &#124; Comunidad de Madrid</description>
	<lastBuildDate>Wed, 15 Jul 2026 06:32:22 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.5</generator>

<image>
	<url>https://www.revalco.es/wp-content/uploads/2025/05/cropped-revalco_favicon-32x32.png</url>
	<title>Protección Diferencial Industrial | Revalco</title>
	<link>https://www.revalco.es</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>TRANSFORMADORES TOROIDALES &#8211; TOR</title>
		<link>https://www.revalco.es/producto/transformadores-toroidales-tor/</link>
					<comments>https://www.revalco.es/producto/transformadores-toroidales-tor/#respond</comments>
		
		<dc:creator><![CDATA[Movatec]]></dc:creator>
		<pubDate>Tue, 03 Jun 2025 11:56:53 +0000</pubDate>
				<guid isPermaLink="false">http://www.revalco.es/?post_type=product&#038;p=18004</guid>

					<description><![CDATA[TRANSFORMADORES TOROIDALES - TOR]]></description>
										<content:encoded><![CDATA[
<table id="tablepress-70" class="tablepress tablepress-id-70 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">DIÁMETRO INTERIOR (MM)</th><th class="column-2">INTENSIDAD NOMINAL</th><th class="column-3">INTENSIDAD MÁXIMA</th><th class="column-4">EJECUCIÓN TOROIDAL</th><th class="column-5">MONTAJE DIN</th><th class="column-6">MONTAJE PANEL</th><th class="column-7">REFERENCIA</th><th class="column-8">PACK</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">ø 35</td><td class="column-2">80A</td><td class="column-3">480A</td><td rowspan="9" class="column-4">NÚCLEO CERRADO</td><td rowspan="9" class="column-5">SI</td><td rowspan="11" class="column-6">SI</td><td class="column-7">TOR3</td><td rowspan="9" class="column-8">1/1</td>
</tr>
<tr class="row-3">
	<td class="column-1">ø 60</td><td class="column-2">120A</td><td class="column-3">720A</td><td class="column-7">TOR6</td>
</tr>
<tr class="row-4">
	<td class="column-1">ø 80</td><td class="column-2">170A</td><td class="column-3">1020A</td><td class="column-7">TOR8</td>
</tr>
<tr class="row-5">
	<td class="column-1">ø 110</td><td class="column-2">260A</td><td class="column-3">1560A</td><td class="column-7">TOR11</td>
</tr>
<tr class="row-6">
	<td class="column-1">ø 160</td><td class="column-2">310A</td><td class="column-3">1860A</td><td class="column-7">TOR16</td>
</tr>
<tr class="row-7">
	<td class="column-1">ø 210</td><td class="column-2">360A</td><td class="column-3">2160A</td><td class="column-7">TOR21</td>
</tr>
<tr class="row-8">
	<td class="column-1">ø 23</td><td class="column-2">80</td><td class="column-3">480A</td><td class="column-7">TOR30</td>
</tr>
<tr class="row-9">
	<td class="column-1">281x156</td><td class="column-2"></td><td class="column-3"></td><td class="column-7">TOR1528</td>
</tr>
<tr class="row-10">
	<td class="column-1">351x170</td><td class="column-2"></td><td class="column-3"></td><td class="column-7">TOR1735</td>
</tr>
<tr class="row-11">
	<td class="column-1">ø 110</td><td class="column-2">260A</td><td class="column-3">1560A</td><td rowspan="2" class="column-4">NÚCLEO PARTIDO</td><td rowspan="2" class="column-5">NO</td><td class="column-7">TORA11</td><td rowspan="2" class="column-8">1/1</td>
</tr>
<tr class="row-12">
	<td class="column-1">ø 210</td><td class="column-2">360A</td><td class="column-3">2160A</td><td class="column-7">TORA21</td>
</tr>
</tbody>
</table>

<p>Estos transformadores de corriente son para aplicaciones que utilizan relés de fuga a tierra. Consisten en un núcleo magnético de alta calidad que detecta corrientes de fallo, incluso de valores muy bajos.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.revalco.es/producto/transformadores-toroidales-tor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>TRANSFORMADORES TOROIDALES TOR1528 &#8211; TOR1735</title>
		<link>https://www.revalco.es/producto/transformadores-toroidales-tor1528-tor1735/</link>
					<comments>https://www.revalco.es/producto/transformadores-toroidales-tor1528-tor1735/#respond</comments>
		
		<dc:creator><![CDATA[Movatec]]></dc:creator>
		<pubDate>Thu, 16 Apr 2026 07:28:52 +0000</pubDate>
				<guid isPermaLink="false">https://www.revalco.es/?post_type=product&#038;p=19878</guid>

					<description><![CDATA[Transformadores Toroidales. Diámetro Interior (mm): TOR1528 281&#215;156 &#8211; TOR1735 351&#215;170 Ejecución Toroidal: Núcleo Cerrado. Montaje DIN: No. Montaje en panel: SI. &#160;]]></description>
										<content:encoded><![CDATA[
<table id="tablepress-70-no-2" class="tablepress tablepress-id-70 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">DIÁMETRO INTERIOR (MM)</th><th class="column-2">INTENSIDAD NOMINAL</th><th class="column-3">INTENSIDAD MÁXIMA</th><th class="column-4">EJECUCIÓN TOROIDAL</th><th class="column-5">MONTAJE DIN</th><th class="column-6">MONTAJE PANEL</th><th class="column-7">REFERENCIA</th><th class="column-8">PACK</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">ø 35</td><td class="column-2">80A</td><td class="column-3">480A</td><td rowspan="9" class="column-4">NÚCLEO CERRADO</td><td rowspan="9" class="column-5">SI</td><td rowspan="11" class="column-6">SI</td><td class="column-7">TOR3</td><td rowspan="9" class="column-8">1/1</td>
</tr>
<tr class="row-3">
	<td class="column-1">ø 60</td><td class="column-2">120A</td><td class="column-3">720A</td><td class="column-7">TOR6</td>
</tr>
<tr class="row-4">
	<td class="column-1">ø 80</td><td class="column-2">170A</td><td class="column-3">1020A</td><td class="column-7">TOR8</td>
</tr>
<tr class="row-5">
	<td class="column-1">ø 110</td><td class="column-2">260A</td><td class="column-3">1560A</td><td class="column-7">TOR11</td>
</tr>
<tr class="row-6">
	<td class="column-1">ø 160</td><td class="column-2">310A</td><td class="column-3">1860A</td><td class="column-7">TOR16</td>
</tr>
<tr class="row-7">
	<td class="column-1">ø 210</td><td class="column-2">360A</td><td class="column-3">2160A</td><td class="column-7">TOR21</td>
</tr>
<tr class="row-8">
	<td class="column-1">ø 23</td><td class="column-2">80</td><td class="column-3">480A</td><td class="column-7">TOR30</td>
</tr>
<tr class="row-9">
	<td class="column-1">281x156</td><td class="column-2"></td><td class="column-3"></td><td class="column-7">TOR1528</td>
</tr>
<tr class="row-10">
	<td class="column-1">351x170</td><td class="column-2"></td><td class="column-3"></td><td class="column-7">TOR1735</td>
</tr>
<tr class="row-11">
	<td class="column-1">ø 110</td><td class="column-2">260A</td><td class="column-3">1560A</td><td rowspan="2" class="column-4">NÚCLEO PARTIDO</td><td rowspan="2" class="column-5">NO</td><td class="column-7">TORA11</td><td rowspan="2" class="column-8">1/1</td>
</tr>
<tr class="row-12">
	<td class="column-1">ø 210</td><td class="column-2">360A</td><td class="column-3">2160A</td><td class="column-7">TORA21</td>
</tr>
</tbody>
</table>
<!-- #tablepress-70-no-2 from cache -->
<p>Transformadores Toroidales.</p>
<ul>
<li>Diámetro Interior (mm): <strong>TOR1528</strong> 281&#215;156 &#8211; <strong>TOR1735</strong> 351&#215;170</li>
<li>Ejecución Toroidal: Núcleo Cerrado.</li>
<li>Montaje DIN: No.</li>
<li>Montaje en panel: SI.</li>
</ul>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.revalco.es/producto/transformadores-toroidales-tor1528-tor1735/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PROTECCIÓN DIFERENCIAL INDUSTRIAL RELÉS DIFERENCIALES MULTIGAMA &#8211; 1RDT1</title>
		<link>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt/</link>
					<comments>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt/#respond</comments>
		
		<dc:creator><![CDATA[Movatec]]></dc:creator>
		<pubDate>Tue, 03 Jun 2025 11:56:52 +0000</pubDate>
				<guid isPermaLink="false">http://www.revalco.es/?post_type=product&#038;p=18003</guid>

					<description><![CDATA[PROTECCIÓN DIFERENCIAL INDUSTRIAL RELÉS DIFERENCIALES MULTIGAMA - 1RDT]]></description>
										<content:encoded><![CDATA[
<table id="tablepress-71" class="tablepress tablepress-id-71 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">DIMENSIONES</th><th class="column-2">TIEMPO DE DISPARO (AJUSTABLE seg)</th><th class="column-3">CLASE</th><th class="column-4">SENSIBILIDAD AJUSTABLE</th><th class="column-5">REFERENCIA</th><th class="column-6">PACK</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">1 MOD DIN</td><td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-100-300-500mA/1 -3A</td><td class="column-5">1RDT1</td><td rowspan="3" class="column-6">1/1</td>
</tr>
<tr class="row-3">
	<td rowspan="2" class="column-1">3 MOD DIN</td><td class="column-2">0-0,25-0,5-1-2-3-4-5-6-7-8-9-10</td><td class="column-3">A</td><td class="column-4">30-350mA/ 3A</td><td class="column-5">1RDT3</td>
</tr>
<tr class="row-4">
	<td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-300-500mA/1 -3-30A</td><td class="column-5">1RDT30E</td>
</tr>
</tbody>
</table>
<!-- #tablepress-71 from cache -->
<p>El control y monitoreo de fuga a tierra consiste en un relé de corriente y un transformador de corriente toroidal de suma asociado que se utilizan en redes de baja tensión con corriente alterna en sistemas TT, IT y TNS. Proporcionan la protección requerida contra contactos indirectos, (protección complementaria contra contactos directos) y contra el riesgo de incendio (como la baja de las corrientes a través de la tierra no son suficientes para permitir que intervenga el dispositivo magnetotérmico). El estándar CEI 64.8 dice que la fuga a tierra, el relé se considera como protección adicional, por lo tanto, no es un dispositivo único para la protección contra los contactos directos. Todos los cables de sistema monofásico o trifásico, incluso el neutro, debe alimentarse a través del toroidal, que es el punto de la corriente residual, el dispositivo se activa cuando detecta el aislamiento defectuoso que se indica cuando la suma vectorial de los cables portadores de corriente da como resultado una fi gura diferencial. Normas: CEI EN 60947.2 / B, CEI 64.8, CEI EN 61008/1 y CEI EN 61010-1.</p>
<p>Para el <strong>1RDT1</strong> se puede suministrar con contacto <strong>NC</strong> bajo pedido.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PROTECCIÓN DIFERENCIAL INDUSTRIAL RELÉS DIFERENCIALES MULTIGAMA &#8211; 1RDT3</title>
		<link>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt3/</link>
					<comments>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt3/#respond</comments>
		
		<dc:creator><![CDATA[Movatec]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 06:27:23 +0000</pubDate>
				<guid isPermaLink="false">https://www.revalco.es/?post_type=product&#038;p=21091</guid>

					<description><![CDATA[El control y monitoreo de fuga a tierra consiste en un relé de corriente y un transformador de corriente toroidal de suma asociado que se utilizan en redes de baja tensión con corriente alterna en sistemas TT, IT y TNS. Proporcionan la protección requerida contra contactos indirectos, (protección complementaria contra contactos directos) y contra el [&#8230;]]]></description>
										<content:encoded><![CDATA[
<table id="tablepress-71-no-2" class="tablepress tablepress-id-71 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">DIMENSIONES</th><th class="column-2">TIEMPO DE DISPARO (AJUSTABLE seg)</th><th class="column-3">CLASE</th><th class="column-4">SENSIBILIDAD AJUSTABLE</th><th class="column-5">REFERENCIA</th><th class="column-6">PACK</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">1 MOD DIN</td><td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-100-300-500mA/1 -3A</td><td class="column-5">1RDT1</td><td rowspan="3" class="column-6">1/1</td>
</tr>
<tr class="row-3">
	<td rowspan="2" class="column-1">3 MOD DIN</td><td class="column-2">0-0,25-0,5-1-2-3-4-5-6-7-8-9-10</td><td class="column-3">A</td><td class="column-4">30-350mA/ 3A</td><td class="column-5">1RDT3</td>
</tr>
<tr class="row-4">
	<td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-300-500mA/1 -3-30A</td><td class="column-5">1RDT30E</td>
</tr>
</tbody>
</table>
<!-- #tablepress-71-no-2 from cache -->
<p>El control y monitoreo de fuga a tierra consiste en un relé de corriente y un transformador de corriente toroidal de suma asociado que se utilizan en redes de baja tensión con corriente alterna en sistemas TT, IT y TNS. Proporcionan la protección requerida contra contactos indirectos, (protección complementaria contra contactos directos) y contra el riesgo de incendio (como la baja de las corrientes a través de la tierra no son suficientes para permitir que intervenga el dispositivo magnetotérmico). El estándar CEI 64.8 dice que la fuga a tierra, el relé se considera como protección adicional, por lo tanto, no es un dispositivo único para la protección contra los contactos directos. Todos los cables de sistema monofásico o trifásico, incluso el neutro, debe alimentarse a través del toroidal, que es el punto de la corriente residual, el dispositivo se activa cuando detecta el aislamiento defectuoso que se indica cuando la suma vectorial de los cables portadores de corriente da como resultado una fi gura diferencial. Normas: CEI EN 60947.2 / B, CEI 64.8, CEI EN 61008/1 y CEI EN 61010-1.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt3/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>PROTECCIÓN DIFERENCIAL INDUSTRIAL RELÉS DIFERENCIALES MULTIGAMA &#8211; 1RDT30E</title>
		<link>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt30e/</link>
					<comments>https://www.revalco.es/producto/proteccion-diferencial-industrial-reles-diferenciales-multigama-1rdt30e/#respond</comments>
		
		<dc:creator><![CDATA[Movatec]]></dc:creator>
		<pubDate>Wed, 15 Jul 2026 06:32:21 +0000</pubDate>
				<guid isPermaLink="false">https://www.revalco.es/?post_type=product&#038;p=21093</guid>

					<description><![CDATA[El control y monitoreo de fuga a tierra consiste en un relé de corriente y un transformador de corriente toroidal de suma asociado que se utilizan en redes de baja tensión con corriente alterna en sistemas TT, IT y TNS. Proporcionan la protección requerida contra contactos indirectos, (protección complementaria contra contactos directos) y contra el [&#8230;]]]></description>
										<content:encoded><![CDATA[
<table id="tablepress-71-no-3" class="tablepress tablepress-id-71 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">DIMENSIONES</th><th class="column-2">TIEMPO DE DISPARO (AJUSTABLE seg)</th><th class="column-3">CLASE</th><th class="column-4">SENSIBILIDAD AJUSTABLE</th><th class="column-5">REFERENCIA</th><th class="column-6">PACK</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">1 MOD DIN</td><td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-100-300-500mA/1 -3A</td><td class="column-5">1RDT1</td><td rowspan="3" class="column-6">1/1</td>
</tr>
<tr class="row-3">
	<td rowspan="2" class="column-1">3 MOD DIN</td><td class="column-2">0-0,25-0,5-1-2-3-4-5-6-7-8-9-10</td><td class="column-3">A</td><td class="column-4">30-350mA/ 3A</td><td class="column-5">1RDT3</td>
</tr>
<tr class="row-4">
	<td class="column-2">0-1-2-3-4</td><td class="column-3">A</td><td class="column-4">30-300-500mA/1 -3-30A</td><td class="column-5">1RDT30E</td>
</tr>
</tbody>
</table>
<!-- #tablepress-71-no-3 from cache -->
<p>El control y monitoreo de fuga a tierra consiste en un relé de corriente y un transformador de corriente toroidal de suma asociado que se utilizan en redes de baja tensión con corriente alterna en sistemas TT, IT y TNS. Proporcionan la protección requerida contra contactos indirectos, (protección complementaria contra contactos directos) y contra el riesgo de incendio (como la baja de las corrientes a través de la tierra no son suficientes para permitir que intervenga el dispositivo magnetotérmico). El estándar CEI 64.8 dice que la fuga a tierra, el relé se considera como protección adicional, por lo tanto, no es un dispositivo único para la protección contra los contactos directos. Todos los cables de sistema monofásico o trifásico, incluso el neutro, debe alimentarse a través del toroidal, que es el punto de la corriente residual, el dispositivo se activa cuando detecta el aislamiento defectuoso que se indica cuando la suma vectorial de los cables portadores de corriente da como resultado una fi gura diferencial. Normas: CEI EN 60947.2 / B, CEI 64.8, CEI EN 61008/1 y CEI EN 61010-1.</p>